Structural Drawings in Kenton HA3
Fixed-fee, MCIAT-chartered structural drawings for Kenton (HA3) homeowners — London Borough of Harrow validation and local constraints handled from the start.
Kenton (HA3) is a 1930s semi-detached suburb straddling the Harrow–Brent border, where the everyday project is a rear kitchen extension, a hip-to-gable or L-shaped dormer loft, or a two-storey side extension that adds a bedroom while keeping the interwar frontage in proportion.
Around the Mount Stewart and Northwick Circle conservation areas we take extra care with roof form, materials and the building line, and we always confirm whether an address falls to Harrow Council so the application is validated first time.


Planning in Kenton (HA3): what to know before you apply
No published householder Article 4 direction, though the Mount Stewart and Northwick Circle conservation areas curb some permitted-development rights; the main watch-points are matching the semi-detached roofline and confirming the correct authority near the Harrow/Brent boundary.
Typical Kenton housing stock
Interwar semi-detached and short terraced houses laid out as a 1930s suburb straddling the Harrow and Brent border, typically with bay windows, hipped roofs and off-street parking. Plots are regular with modest-to-generous rear gardens well suited to single-storey additions.
Streets we regularly draw for in Kenton
The Ridgeway · Draycott Avenue · Windermere Avenue · Northwick Circle
What HA3 is actually built of
Measured from 245 classified residential buildings in HA3, not from a description of the area.
Kenton HA3 housing mix
Residential building form across the HA3 postcode district, from 245 classified buildings.
| Attached on more than one side | 41% |
|---|---|
| Attached on one side | 51% |
| Detached | 9% |
| Median building footprint | 72 m² |
| Addresses per buildingAbove about 2 means flats and maisonettes dominate | 1.18 |
| Buildings classified | 245 |
Source: Ordnance Survey National Geographic Database (derived statistics). Contains OS data © Crown copyright and database right 2026. Contains Royal Mail data © Royal Mail copyright and database right 2026. Extracted 2026-08-17.
Structural Drawings for Kenton (HA3) homes: the package and the process
Structural sheets are issued to be built from. Beam and lintel schedules give size, grade and bearing; connection details show how each element meets the next; and padstones, straps and restraint are drawn at the junctions rather than noted in general terms. Calculations are submitted alongside so Building Control can check the design rather than take it on trust.
Coordination with the architectural set is where the value is. A beam that is right in isolation but sits below the approved ceiling line, or a column that lands in a doorway, is a site problem that costs more to fix than it did to draw. We resolve those clashes in the drawing stage.
The existing structure sets the design. A terrace transfers load through party walls that are shared and often unrecorded, a semi through one; and floor construction — timber, concrete, or a mix from earlier alterations — changes how a new opening is supported and what has to be exposed to find out.
Do I need structural calculations to remove a load-bearing wall in London?
If a wall carries any load from above — a floor, a roof, another wall, or a chimney breast — you need a structural calculation before it can be removed, and Building Control will ask for it as part of a Full Plans or Building Notice submission. This covers the great majority of kitchen-diner knock-throughs in London terraces and semis, where the wall between the kitchen and the rear reception room is almost always load-bearing. A calculation confirms the size and type of steel beam needed to replace the wall's support, the padstones or pier that carry the beam's weight down to the foundations, and the temporary propping needed while the work is carried out. If the wall shares a boundary or the new beam bears on a party wall, the Party Wall etc. Act 1996 will also apply and needs to be dealt with separately from the calculation itself.
How steel beam sizing works
A structural engineer calculates the loads bearing down on a wall from the floors, roof and any walls above it, then sizes a steel beam (RSJ) — its depth, width and steel grade — so it can safely carry that load across the required span without excessive deflection. The calculation also fixes the bearing length at each end, the padstones or steel plates that spread the load into the surrounding masonry, and whether the existing foundations need strengthening to take the extra point loads. Because we coordinate the calculation with the architectural drawing set, the exact beam size, orientation and position shown on your plans is the one the calculation specifies — so your builder can order the correct steel first time, and Building Control sees a consistent set of drawings rather than two documents that disagree.
How much do structural drawings cost in London?
Structural drawings and calculations start from £650 for a single beam or wall removal, agreed as a fixed fee before work begins. The price depends on the number of beams or walls involved, whether foundations need designing from scratch (as with a rear or side extension), whether existing floor and roof structures need checking for extra loading (as with most loft conversions), and whether retaining or underpinning calculations are required, as they are for basement conversions. Where structural work is part of a wider extension, loft or basement project, the structural calculation is typically bundled into the overall building regulations fee rather than charged again separately.
| Project scope | What's included | Fee guide |
|---|---|---|
| Single beam or wall removal | One steel calculation plus a drawing showing beam size, padstones and bearings | From £650 |
| Loft conversion structural package | Floor and roof loading checks, beam calculations, staircase opening design | Included within loft drawings from £1,100 |
| Rear or side extension structural package | Foundation design, steel beam calculations, roof loading checks | Included within planning and building regs packages from £2,200–£3,850 |
| Basement or retaining structure | Underpinning, retaining wall and waterproofing-adjacent structural calculations | Quoted individually — ground conditions vary |

Structural Drawings in Kenton HA3 — FAQs
Do I need a structural engineer to remove a wall in my London home?+
How long do structural calculations take?+
Will the steel beam on my drawings match what my builder orders?+
Can you produce structural drawings without handling my full planning application?+
Do structural calculations need to be submitted to Building Control?+
Do I need planning permission for a loft conversion in Harrow?+
What does Harrow expect for a rear extension on a 1930s semi?+
Can I extend a home in Harrow on the Hill or Pinner?+
How long does Harrow Council take to decide?+
How much do planning drawings cost in Harrow?+