Structural Drawings in West Ealing W13
Fixed-fee, MCIAT-chartered structural drawings for West Ealing (W13) homeowners — London Borough of Ealing validation and local constraints handled from the start.
In West Ealing (W13) we draw up planning and building-control packages for rear kitchen extensions, loft conversions and refurbishments on the district's Edwardian terraces and villas.
The St Stephen's and Ealing Green conservation areas mean side extensions and roof changes get closer scrutiny, so we check whether your address sits inside the boundary before choosing between permitted development and a full application.


Planning in West Ealing (W13): what to know before you apply
There is no Article 4 direction on the W13 conservation areas, but conservation-area status still removes some permitted-development rights and adds design scrutiny. Homes outside the boundary often keep full rear-extension and loft PD allowances, which we confirm case by case.
Typical West Ealing housing stock
West Ealing is dominated by late-Victorian and Edwardian terraces and semi-detached villas laid out around Northfield Avenue and the St Stephen's streets, many with generous rear gardens suited to extensions.
Streets we regularly draw for in West Ealing
St Stephen's Road · St Stephen's Avenue · Craven Avenue · Cleveland Road
What W13 is actually built of
Measured from 369 classified residential buildings in W13, not from a description of the area.
West Ealing W13 housing mix
Residential building form across the W13 postcode district, from 369 classified buildings.
| Attached on more than one side | 50% |
|---|---|
| Attached on one side | 44% |
| Detached | 7% |
| Median building footprint | 67 m² |
| Addresses per buildingAbove about 2 means flats and maisonettes dominate | 1.84 |
| Buildings classified | 369 |
Source: Ordnance Survey National Geographic Database (derived statistics). Contains OS data © Crown copyright and database right 2026. Contains Royal Mail data © Royal Mail copyright and database right 2026. Extracted 2026-08-17.
Structural Drawings for West Ealing (W13) homes: the package and the process
Structural sheets are issued to be built from. Beam and lintel schedules give size, grade and bearing; connection details show how each element meets the next; and padstones, straps and restraint are drawn at the junctions rather than noted in general terms. Calculations are submitted alongside so Building Control can check the design rather than take it on trust.
Coordination with the architectural set is where the value is. A beam that is right in isolation but sits below the approved ceiling line, or a column that lands in a doorway, is a site problem that costs more to fix than it did to draw. We resolve those clashes in the drawing stage.
The existing structure sets the design. A terrace transfers load through party walls that are shared and often unrecorded, a semi through one; and floor construction — timber, concrete, or a mix from earlier alterations — changes how a new opening is supported and what has to be exposed to find out.
Do I need structural calculations to remove a load-bearing wall in London?
If a wall carries any load from above — a floor, a roof, another wall, or a chimney breast — you need a structural calculation before it can be removed, and Building Control will ask for it as part of a Full Plans or Building Notice submission. This covers the great majority of kitchen-diner knock-throughs in London terraces and semis, where the wall between the kitchen and the rear reception room is almost always load-bearing. A calculation confirms the size and type of steel beam needed to replace the wall's support, the padstones or pier that carry the beam's weight down to the foundations, and the temporary propping needed while the work is carried out. If the wall shares a boundary or the new beam bears on a party wall, the Party Wall etc. Act 1996 will also apply and needs to be dealt with separately from the calculation itself.
How steel beam sizing works
A structural engineer calculates the loads bearing down on a wall from the floors, roof and any walls above it, then sizes a steel beam (RSJ) — its depth, width and steel grade — so it can safely carry that load across the required span without excessive deflection. The calculation also fixes the bearing length at each end, the padstones or steel plates that spread the load into the surrounding masonry, and whether the existing foundations need strengthening to take the extra point loads. Because we coordinate the calculation with the architectural drawing set, the exact beam size, orientation and position shown on your plans is the one the calculation specifies — so your builder can order the correct steel first time, and Building Control sees a consistent set of drawings rather than two documents that disagree.
How much do structural drawings cost in London?
Structural drawings and calculations start from £650 for a single beam or wall removal, agreed as a fixed fee before work begins. The price depends on the number of beams or walls involved, whether foundations need designing from scratch (as with a rear or side extension), whether existing floor and roof structures need checking for extra loading (as with most loft conversions), and whether retaining or underpinning calculations are required, as they are for basement conversions. Where structural work is part of a wider extension, loft or basement project, the structural calculation is typically bundled into the overall building regulations fee rather than charged again separately.
| Project scope | What's included | Fee guide |
|---|---|---|
| Single beam or wall removal | One steel calculation plus a drawing showing beam size, padstones and bearings | From £650 |
| Loft conversion structural package | Floor and roof loading checks, beam calculations, staircase opening design | Included within loft drawings from £1,100 |
| Rear or side extension structural package | Foundation design, steel beam calculations, roof loading checks | Included within planning and building regs packages from £2,200–£3,850 |
| Basement or retaining structure | Underpinning, retaining wall and waterproofing-adjacent structural calculations | Quoted individually — ground conditions vary |

Structural Drawings in West Ealing W13 — FAQs
Do I need a structural engineer to remove a wall in my London home?+
How long do structural calculations take?+
Will the steel beam on my drawings match what my builder orders?+
Can you produce structural drawings without handling my full planning application?+
Do structural calculations need to be submitted to Building Control?+
Do I need planning permission for a rear extension in Ealing?+
What extra control applies in Bedford Park?+
How long does Ealing Council take to decide a householder application?+
Can you help with a loft conversion on a 1930s Ealing semi?+
How much do planning drawings cost in Ealing?+
Get your free West Ealing planning assessment
Tell us your West Ealing (W13) address and ambition — we'll confirm feasibility, local constraints and a fixed fee within one working day.