Rear Extension Drawings in Emerson Park RM11
Fixed-fee, MCIAT-chartered rear extension drawings for Emerson Park (RM11) homeowners — London Borough of Havering validation and local constraints handled from the start.
Emerson Park in RM11 is Havering's most affluent suburb, characterised by large detached interwar houses on wide, tree-lined plots. Work here skews toward ambitious schemes: two-storey and wrap-around extensions, outbuildings, annexes and occasionally full replacement dwellings where the plot supports it.
The spacious, green character means London Borough of Havering scrutinises massing, spacing between houses and tree protection closely, and the Langtons and St Andrew's conservation areas nearby reinforce that heritage backdrop, so we design larger schemes to sit convincingly within the established grain.


Planning in Emerson Park (RM11): what to know before you apply
No published householder Article 4 direction applies in Emerson Park; the practical constraints are protected trees, generous building lines and the low-density character, with the Langtons and St Andrew's Hornchurch conservation areas nearby. Larger plots often support extensions beyond permitted development via full applications.
Typical Emerson Park housing stock
Emerson Park is a leafy, affluent interwar suburb of large detached houses on wide, deep plots between Hornchurch and Upminster. Generous frontages and spacious gardens make it a hotspot for substantial two-storey and wrap-around extensions, garages, outbuildings and full replacement dwellings.
Streets we regularly draw for in Emerson Park
Hazel Rise · Great Gardens Road · Warrington Gardens · Maybrick Road
What RM11 is actually built of
Measured from 318 classified residential buildings in RM11, not from a description of the area.
Emerson Park RM11 housing mix
Residential building form across the RM11 postcode district, from 318 classified buildings.
| Attached on more than one side | 20% |
|---|---|
| Attached on one side | 57% |
| Detached | 23% |
| Median building footprint | 75 m² |
| Addresses per buildingAbove about 2 means flats and maisonettes dominate | 1.13 |
| Buildings classified | 318 |
Source: Ordnance Survey National Geographic Database (derived statistics). Contains OS data © Crown copyright and database right 2026. Contains Royal Mail data © Royal Mail copyright and database right 2026. Extracted 2026-08-17.
Rear Extension Drawings for Emerson Park (RM11) homes: the package and the process
Depth is the number the application turns on, and it has to be measured from the original rear wall of the house rather than from whatever is there now. The drawings carry that dimension, the eaves and ridge heights, the position of any rooflight, and the boundary distances on both sides.
Where the scheme goes beyond the standard allowance and relies on the larger home extension route, the drawings serve a second purpose: they are what the council sends to the neighbours during the consultation. A clear, dimensioned proposed elevation answers the objection about overshadowing before it is made.
Depth is limited by the plot as much as by the rules. A long garden behind a terrace can take the full allowance, while a short one runs out before the rules do — and on a semi or detached house the same depth reads very differently from the boundary.
Do I need planning permission for a rear extension in London?
Many single-storey rear extensions qualify as permitted development, meaning no planning application is needed, provided depth, height and materials stay within set limits. That changes if your property sits in a conservation area or is subject to an Article 4 direction, both of which can remove permitted development rights across a street or borough — in that case a full householder planning application is required regardless of size.
Even where an extension qualifies, most homeowners obtain a Lawful Development Certificate to confirm that status in writing before building — useful for mortgage lenders, buyers and Building Control. We check your property against your borough's constraints before recommending a route.
How deep can a single-storey rear extension go?
Depth is the main constraint on a rear extension, and it depends on your house type and whether you use standard permitted development or the larger home extension scheme.
Permitted development
Standard permitted development allows a single-storey rear extension up to 3 metres deep for terraced and semi-detached houses, or 4 metres for detached houses, generally with eaves height limited to match or stay close to the existing house.
Larger home extension scheme
The prior-approval scheme extends this to 6 metres for terraced and semi-detached houses and 8 metres for detached houses. Your council writes to affected neighbours; if none object within the notification period, approval follows without a full planning application. If an objection is raised, the council assesses the impact on neighbouring light and outlook itself, rather than automatically refusing, so a well-considered design still has a good chance of approval.
Designing the kitchen-diner: rooflights, bi-folds and daylight
Most rear extensions exist to create one open-plan kitchen, dining and living space, so the drawing work focuses on getting light and flow right within the depth you are allowed.
- Structural opening sized for bi-fold or sliding doors across most of the rear elevation
- Rooflights or a roof lantern positioned to light the centre of the room, away from the shadow line of the main house
- Open-plan layout tested against the 45-degree rule, which protects daylight to your neighbours' windows and can limit how close a flank wall or roof comes to the boundary
- Floor build-up and threshold detail coordinated so the new floor meets the existing one without a step
| Route | When it applies | Typical fee |
|---|---|---|
| Permitted development (Lawful Development Certificate) | Depth within 3m (terraced/semi) or 4m (detached), height and materials within PD limits | PD/LDC pack ~£950–£1,450 |
| Larger home extension (prior approval) | Depth up to 6m (terraced/semi) or 8m (detached), with neighbour notification | from £1,100 |
| Full householder planning permission | Extension exceeds PD/larger-home limits, or the property is in a conservation area with an Article 4 direction | Full Planning pack ~£1,600–£2,400 |
| Planning + Building Regulations (structural) | Combined planning and construction-ready pack with structural calculations for the opening and roof | Planning + Building Regs pack ~£2,200–£3,850 |

Rear Extension Drawings in Emerson Park RM11 — FAQs
How much does a rear extension cost to design in London?+
Do I need an architect for a rear extension?+
How long does it take to get rear extension drawings?+
What is the 45-degree rule?+
Will I need a Party Wall Agreement for a rear extension?+
Do I need planning permission for an extension in Havering?+
How does green-belt land affect my Havering project?+
Can I build a bigger extension because Havering plots are larger?+
How long does Havering Council take to decide?+
How much do planning drawings cost in Havering?+
Get your free Emerson Park planning assessment
Tell us your Emerson Park (RM11) address and ambition — we'll confirm feasibility, local constraints and a fixed fee within one working day.