Planning Drawings in Kenton HA3
Fixed-fee, MCIAT-chartered planning drawings for Kenton (HA3) homeowners — London Borough of Harrow validation and local constraints handled from the start.
Kenton (HA3) is a 1930s semi-detached suburb straddling the Harrow–Brent border, where the everyday project is a rear kitchen extension, a hip-to-gable or L-shaped dormer loft, or a two-storey side extension that adds a bedroom while keeping the interwar frontage in proportion.
Around the Mount Stewart and Northwick Circle conservation areas we take extra care with roof form, materials and the building line, and we always confirm whether an address falls to Harrow Council so the application is validated first time.


Planning in Kenton (HA3): what to know before you apply
No published householder Article 4 direction, though the Mount Stewart and Northwick Circle conservation areas curb some permitted-development rights; the main watch-points are matching the semi-detached roofline and confirming the correct authority near the Harrow/Brent boundary.
Typical Kenton housing stock
Interwar semi-detached and short terraced houses laid out as a 1930s suburb straddling the Harrow and Brent border, typically with bay windows, hipped roofs and off-street parking. Plots are regular with modest-to-generous rear gardens well suited to single-storey additions.
Streets we regularly draw for in Kenton
The Ridgeway · Draycott Avenue · Windermere Avenue · Northwick Circle
What HA3 is actually built of
Measured from 245 classified residential buildings in HA3, not from a description of the area.
Kenton HA3 housing mix
Residential building form across the HA3 postcode district, from 245 classified buildings.
| Attached on more than one side | 41% |
|---|---|
| Attached on one side | 51% |
| Detached | 9% |
| Median building footprint | 72 m² |
| Addresses per buildingAbove about 2 means flats and maisonettes dominate | 1.18 |
| Buildings classified | 245 |
Source: Ordnance Survey National Geographic Database (derived statistics). Contains OS data © Crown copyright and database right 2026. Contains Royal Mail data © Royal Mail copyright and database right 2026. Extracted 2026-08-17.
Planning Drawings for Kenton (HA3) homes: the package and the process
A planning set is judged as a set, not as individual sheets. Every existing drawing needs its proposed counterpart at the same scale and orientation so the officer can read the change at a glance, each sheet needs its own number, title, scale bar and north point, and the whole package needs to survive being printed at A3 without a dimension becoming illegible.
We draw to the conventions validation teams expect: plans and elevations at 1:100 or 1:50, a location plan at 1:1250 with the site edged red, a block plan at 1:500, and sections cut where the change in level or roof form actually happens rather than where they are easiest to draw.
The drawing list itself changes with the building. A detached house needs four elevations; a mid-terrace needs two plus a section through the party walls to show what is not visible from outside. Getting that list right at the start is what stops a validation officer asking for a sheet three weeks in.
What is included in a planning drawing set?
A council will only validate an application that contains the right drawings at the right scale. Our standard planning set covers everything a London validation team expects.
- Site location plan (1:1250) and block plan (1:500)
- Existing floor plans, elevations and sections
- Proposed floor plans, elevations and sections
- Roof plans where relevant, with heights and materials annotated
- A design and access or heritage statement where the borough requires one
How are planning drawings different from building regulations drawings?
Planning drawings show what the building will look like and how it sits in its context. Building regulations drawings show how it will be built safely — structure, insulation, fire escape and drainage. Most projects need both; our Complete package covers the two together with structural calculations coordinated in-house.
How quickly can you produce planning drawings in London?
After a laser survey, a standard householder set is typically ready within 7 days. We review every drawing against your borough's validation checklist before it reaches a planner's desk, which is why our first-time approval rate sits around 96%.
| Drawing | Typical scale | What it shows |
|---|---|---|
| Site location plan | 1:1250 | The property in its street context, site edged red |
| Block plan | 1:500 | The building's footprint and position in the plot |
| Floor plans (existing & proposed) | 1:100 / 1:50 | Room layout, walls, openings and the proposed changes |
| Elevations (existing & proposed) | 1:100 / 1:50 | Each face of the building and how it changes |
| Sections | 1:100 / 1:50 | A cut through showing heights, levels and roof form |

Planning Drawings in Kenton HA3 — FAQs
What scale should London planning drawings be?+
Do I need an architect to produce planning drawings?+
How many revisions are included in the fee?+
Can you draw from my existing plans?+
Do planning drawings guarantee approval?+
Do I need planning permission for a loft conversion in Harrow?+
What does Harrow expect for a rear extension on a 1930s semi?+
Can I extend a home in Harrow on the Hill or Pinner?+
How long does Harrow Council take to decide?+
How much do planning drawings cost in Harrow?+
Get your free Kenton planning assessment
Tell us your Kenton (HA3) address and ambition — we'll confirm feasibility, local constraints and a fixed fee within one working day.