
Basement Conversion Drawings in Kennington SE11
Fixed-fee, MCIAT-chartered basement conversion drawings for Kennington (SE11) homeowners — London Borough of Lambeth validation and local constraints handled from the start.
Kennington SE11 is a tight grid of late-Georgian and early-Victorian terraces a short walk from the Oval, where most homeowners look to rear kitchen extensions and loft conversions to add space without altering the protected street frontage.
Because the Kennington and Walcot Conservation Areas cover much of the outcode, we always confirm which boundary a property sits inside before advising permitted development versus a full householder application — conservation-area status quietly removes several rights a comparable house outside would keep.


Planning in Kennington (SE11): what to know before you apply
Most Kennington projects run as full householder applications to Lambeth given the conservation-area coverage, with rear extensions and rooflight lofts the usual approvable route. Front and roof changes need the closest attention. We check the exact CA boundary and any listing before choosing the route.
Typical Kennington housing stock
Smart brick terraces that grew from the late 18th century onward, including the Georgian set pieces around Cleaver Square. Many are three- and four-storey flat-fronted houses, now often split into flats or run as family homes with scope for rear and lower-ground extensions.
Streets we regularly draw for in Kennington
Cleaver Square · Cardigan Street · Courtenay Street · Kennington Road
What SE11 is actually built of
Measured from 291 classified residential buildings in SE11, not from a description of the area.
Kennington SE11 housing mix
Residential building form across the SE11 postcode district, from 291 classified buildings.
| Attached on more than one side | 73% |
|---|---|
| Attached on one side | 23% |
| Detached | 4% |
| Median building footprint | 59 m² |
| Addresses per buildingAbove about 2 means flats and maisonettes dominate | 4.87 |
| Buildings classified | 291 |
Source: Ordnance Survey National Geographic Database (derived statistics). Contains OS data © Crown copyright and database right 2026. Contains Royal Mail data © Royal Mail copyright and database right 2026. Extracted 2026-08-17.
Basement Conversion Drawings for Kennington (SE11) homes: the package and the process
A basement package is led by its section. It has to show the existing structure, the proposed floor level, retained or underpinned walls, the tanking system, and how the finished room achieves head height without undermining what sits above. Structural design and architectural design are drawn together because here they are the same decision.
Habitable basement rooms also need light, ventilation and escape. The drawings set out lightwells and their guarding, mechanical ventilation where natural is not achievable, and an escape route that Building Control will accept — usually a protected stair, sometimes an external route out of the lightwell.
What sits below the house decides the route. An existing cellar under a Victorian terrace is a conversion with a known volume, while a house with no cellar is a dig-out with underpinning, structural design and a very different drawing set — and the two are rarely interchangeable.
Do I need planning permission for a basement conversion in London?
An internal conversion of an existing cellar — new floor, insulation, a habitable layout — often does not need planning permission, because the works sit entirely within the existing structure and do not change its external appearance. Digging out a new basement, lowering an existing floor to gain headroom, or enlarging the footprint under a garden usually does, particularly where excavation extends beyond the existing building line. Any external alteration needed to serve the basement — a front light well, a sunken external staircase, or altering the pavement or front garden — is also likely to need planning permission in its own right, even when the basement works themselves would not. In a conservation area, a front light well tends to draw closer scrutiny than the same feature elsewhere, since it changes the street-facing elevation and the pavement it sits within — one more reason we assess the whole scheme, not just the room below ground, before recommending a route.
Cellar conversion or new dig-out — which route fits your property?
The two starting points lead to very different drawing sets. A cellar conversion works with a void that already exists: the drawings focus on damp-proofing, insulation, headroom, natural or borrowed light, means of escape and a compliant layout, coordinated with building regulations rather than planning.
A new dig-out or floor-lowering project starts from a structural decision — how the existing foundations will be underpinned to allow excavation beneath them — and the drawings and structural calculations are produced together from the outset, since the sequence of underpinning, temporary works and waterproofing has to be engineered before a builder can safely start.
What structural design does underpinning a basement need?
Lowering a floor or digging a new basement beneath an existing house means underpinning its foundations in sequenced sections, so the building above stays supported throughout. We produce the structural drawings and calculations for the underpinning sequence, any new steel beams or retaining walls, and the interaction with neighbouring foundations, in-house as part of the same package — so your structural engineer sign-off and your architectural drawings are never out of step with each other.
The sequencing matters as much as the sizing: underpinning is dug and cast in short, alternating sections so the existing wall is never left unsupported over any significant length, and the drawings set out the order those sections are worked in alongside the retaining and waterproofing detail. Getting that sequence wrong is one of the most common causes of cracking and delay on a basement project, which is why we treat it as a design decision rather than something left for the contractor to work out on site.
| Route | Typical scope | Planning position | Fee from |
|---|---|---|---|
| Existing cellar conversion | Fit-out of an existing void, no excavation | Usually building regulations only | £2,400 |
| Floor lowering / partial dig-out | Increases headroom within the existing footprint | Often needs planning permission | £3,200 |
| New-build basement or light well extension | New basement area beyond the existing footprint | Full planning plus Party Wall Act | £3,850 |

Basement Conversion Drawings in Kennington SE11 — FAQs
How much do basement conversion drawings cost in London?+
Does a basement conversion need planning permission?+
Will I need a party wall agreement for a basement conversion?+
Are structural calculations included in a basement conversion package?+
Do I need an architect for a basement conversion?+
Do I need planning permission for a side-return extension in Lambeth?+
My Lambeth home is a converted flat — does that change things?+
What does Lambeth's HMO Article 4 direction affect?+
How long does Lambeth Council take to decide?+
How much do planning drawings cost in Lambeth?+
Get your free Kennington planning assessment
Tell us your Kennington (SE11) address and ambition — we'll confirm feasibility, local constraints and a fixed fee within one working day.