Structural Drawings in Southall UB2
Fixed-fee, MCIAT-chartered structural drawings for Southall (UB2) homeowners — London Borough of Ealing validation and local constraints handled from the start.
In Southall (UB2) we produce planning and building-regulation drawings for rear extensions, side-return kitchens and loft conversions on the area's Edwardian and interwar homes.
Where a plot sits within or near the Canalside conservation area we check the boundary and the canal-frontage constraints first, then advise whether the work is permitted development or needs a full planning application.


Planning in Southall (UB2): what to know before you apply
Most UB2 homes away from the canal retain permitted-development rights for rear extensions and lofts. Plots inside the Canalside conservation area face tighter control on anything visible from the towpath, and the Blue Ribbon/SINC designation adds ecology checks near the water.
Typical Southall housing stock
South Southall (UB2) is largely Edwardian and interwar terraces and semis around Norwood Green and Tentelow Lane, with the Grand Union Canal corridor forming the Canalside conservation area along its southern edge.
Streets we regularly draw for in Southall
Norwood Road · Tentelow Lane · Osterley Park Road · Regina Road
What UB2 is actually built of
Measured from 379 classified residential buildings in UB2, not from a description of the area.
Southall UB2 housing mix
Residential building form across the UB2 postcode district, from 379 classified buildings.
| Attached on more than one side | 50% |
|---|---|
| Attached on one side | 45% |
| Detached | 5% |
| Median building footprint | 65 m² |
| Addresses per buildingAbove about 2 means flats and maisonettes dominate | 1.27 |
| Buildings classified | 379 |
Source: Ordnance Survey National Geographic Database (derived statistics). Contains OS data © Crown copyright and database right 2026. Contains Royal Mail data © Royal Mail copyright and database right 2026. Extracted 2026-08-17.
Structural Drawings for Southall (UB2) homes: the package and the process
Structural sheets are issued to be built from. Beam and lintel schedules give size, grade and bearing; connection details show how each element meets the next; and padstones, straps and restraint are drawn at the junctions rather than noted in general terms. Calculations are submitted alongside so Building Control can check the design rather than take it on trust.
Coordination with the architectural set is where the value is. A beam that is right in isolation but sits below the approved ceiling line, or a column that lands in a doorway, is a site problem that costs more to fix than it did to draw. We resolve those clashes in the drawing stage.
The existing structure sets the design. A terrace transfers load through party walls that are shared and often unrecorded, a semi through one; and floor construction — timber, concrete, or a mix from earlier alterations — changes how a new opening is supported and what has to be exposed to find out.
Do I need structural calculations to remove a load-bearing wall in London?
If a wall carries any load from above — a floor, a roof, another wall, or a chimney breast — you need a structural calculation before it can be removed, and Building Control will ask for it as part of a Full Plans or Building Notice submission. This covers the great majority of kitchen-diner knock-throughs in London terraces and semis, where the wall between the kitchen and the rear reception room is almost always load-bearing. A calculation confirms the size and type of steel beam needed to replace the wall's support, the padstones or pier that carry the beam's weight down to the foundations, and the temporary propping needed while the work is carried out. If the wall shares a boundary or the new beam bears on a party wall, the Party Wall etc. Act 1996 will also apply and needs to be dealt with separately from the calculation itself.
How steel beam sizing works
A structural engineer calculates the loads bearing down on a wall from the floors, roof and any walls above it, then sizes a steel beam (RSJ) — its depth, width and steel grade — so it can safely carry that load across the required span without excessive deflection. The calculation also fixes the bearing length at each end, the padstones or steel plates that spread the load into the surrounding masonry, and whether the existing foundations need strengthening to take the extra point loads. Because we coordinate the calculation with the architectural drawing set, the exact beam size, orientation and position shown on your plans is the one the calculation specifies — so your builder can order the correct steel first time, and Building Control sees a consistent set of drawings rather than two documents that disagree.
How much do structural drawings cost in London?
Structural drawings and calculations start from £650 for a single beam or wall removal, agreed as a fixed fee before work begins. The price depends on the number of beams or walls involved, whether foundations need designing from scratch (as with a rear or side extension), whether existing floor and roof structures need checking for extra loading (as with most loft conversions), and whether retaining or underpinning calculations are required, as they are for basement conversions. Where structural work is part of a wider extension, loft or basement project, the structural calculation is typically bundled into the overall building regulations fee rather than charged again separately.
| Project scope | What's included | Fee guide |
|---|---|---|
| Single beam or wall removal | One steel calculation plus a drawing showing beam size, padstones and bearings | From £650 |
| Loft conversion structural package | Floor and roof loading checks, beam calculations, staircase opening design | Included within loft drawings from £1,100 |
| Rear or side extension structural package | Foundation design, steel beam calculations, roof loading checks | Included within planning and building regs packages from £2,200–£3,850 |
| Basement or retaining structure | Underpinning, retaining wall and waterproofing-adjacent structural calculations | Quoted individually — ground conditions vary |

Structural Drawings in Southall UB2 — FAQs
Do I need a structural engineer to remove a wall in my London home?+
How long do structural calculations take?+
Will the steel beam on my drawings match what my builder orders?+
Can you produce structural drawings without handling my full planning application?+
Do structural calculations need to be submitted to Building Control?+
Do I need planning permission for a rear extension in Ealing?+
What extra control applies in Bedford Park?+
How long does Ealing Council take to decide a householder application?+
Can you help with a loft conversion on a 1930s Ealing semi?+
How much do planning drawings cost in Ealing?+
Get your free Southall planning assessment
Tell us your Southall (UB2) address and ambition — we'll confirm feasibility, local constraints and a fixed fee within one working day.