
HMO Conversion Drawings in Deptford SE8
Fixed-fee, MCIAT-chartered hmo conversion drawings for Deptford (SE8) homeowners — London Borough of Lewisham validation and local constraints handled from the start.
Deptford (SE8) mixes rare early-Georgian houses around St Paul's church with Victorian terraces and later flats between Deptford Creek and the A2, and our work here ranges from side-return kitchens to loft conversions on the terraced streets behind the High Street.
Because Lewisham made an Article 4 direction for the Deptford High Street and St Paul's Church Conservation Area in 2021, many normally-permitted changes now need consent, so we confirm the boundary before choosing between a permitted-development route and a full householder application.


Planning in Deptford (SE8): what to know before you apply
Inside the conservation area the Article 4 direction means street-facing alterations that would elsewhere be permitted development now require planning permission. We prepare drawings and, where needed, heritage-aware householder applications to Lewisham standards.
Typical Deptford housing stock
Around St Paul's church and the High Street survive rare 17th, 18th and early-19th-century houses, with Victorian terraces, former workshops and later social housing filling the streets between the Creek and the A2.
Streets we regularly draw for in Deptford
Deptford High Street · Albury Street · Crossfield Street · Watergate Street
What SE8 is actually built of
Measured from 170 classified residential buildings in SE8, not from a description of the area.
Deptford SE8 housing mix
Residential building form across the SE8 postcode district, from 170 classified buildings.
| Attached on more than one side | 72% |
|---|---|
| Attached on one side | 21% |
| Detached | 7% |
| Median building footprint | 58 m² |
| Addresses per buildingAbove about 2 means flats and maisonettes dominate | 5.24 |
| Buildings classified | 170 |
Source: Ordnance Survey National Geographic Database (derived statistics). Contains OS data © Crown copyright and database right 2026. Contains Royal Mail data © Royal Mail copyright and database right 2026. Extracted 2026-08-17.
HMO Conversion Drawings for Deptford (SE8) homes: the package and the process
An HMO scheme is drawn against a schedule. Every bedroom is dimensioned with its usable floor area stated, shared kitchen and bathroom provision is counted against the number of occupants, and the layout has to hold up against the space standards the licensing team applies.
The fire strategy is drawn, not described: protected escape route, fire doors and their ratings, alarm coverage by room, and compartmentation between floors. Licensing and building control assess the same drawing set from different angles, so it has to satisfy both without contradiction.
Room count is a function of the existing plan. A large semi or detached house with generous rooms can meet the space standards without subdivision, while a narrow terrace usually cannot reach the same occupancy without creating rooms that fall below the minimum floor area.
C4 small HMO or sui generis large HMO — which applies to your property?
The distinction matters because it decides which rules apply. A small HMO housing three to six unrelated sharers who share amenities is Class C4. A large HMO of seven or more occupants is sui generis and always needs planning permission, since sui generis uses sit outside the permitted development system entirely. The line also shifts with occupancy — a property let to six sharers today can tip into sui generis territory the moment a seventh tenancy is signed, which changes the planning position even though nothing about the building itself has changed. We assess your proposed occupancy and layout against both definitions before drawing, so the application matches how the property will actually be let.
Do I need planning permission for an HMO conversion in London?
Converting a family home (C3) into a small HMO (C4) is technically permitted development under national rules, but a large number of London boroughs have made an Article 4 direction that removes this right across all or part of the borough — meaning a full planning application is required even for a small, compliant HMO. Article 4 directions vary street by street in some boroughs, so two similar houses a few doors apart can sit on opposite sides of the line. Any large HMO (sui generis) needs planning permission everywhere, regardless of Article 4. We check your specific address against the relevant borough's Article 4 direction before recommending a route, since guessing wrong wastes both time and application fees.
Mandatory and additional HMO licensing — what's required?
Most HMOs need a licence from the council, separate from any planning permission. A licence application typically has to demonstrate that the property meets fire safety, amenity and space standards, that gas and electrical installations are safety-certified, and that the landlord or managing agent is a fit and proper person to hold it.
Mandatory licensing
Applies to any HMO of five or more occupants forming two or more households, regardless of the number of storeys — a national requirement in every London borough.
Additional licensing
Many boroughs extend licensing to smaller HMOs, typically three or four occupants, across all or part of their area. We check the current scheme for your borough before you apply, since schemes and boundaries change.
| Factor | C4 small HMO (3–6 sharers) | Sui generis large HMO (7+) |
|---|---|---|
| Use class | C4 | Sui generis |
| Planning permission | Often needed due to Article 4 directions in most boroughs | Always needed |
| Licensing | Mandatory if 5+ occupants; additional licensing in many boroughs | Mandatory |
| Typical drawing package | From £1,400 | Full planning + building regs, from £2,200 |

HMO Conversion Drawings in Deptford SE8 — FAQs
How much do HMO conversion drawings cost in London?+
Is HMO conversion permitted development in London?+
Do I need a licence as well as planning permission?+
Do I need an architect for an HMO conversion?+
How long do HMO conversion drawings take?+
Do I need planning permission for a side-return extension in Lewisham?+
What does Lewisham's borough-wide HMO Article 4 direction affect?+
Can I convert the loft on my Lewisham terrace?+
How long does Lewisham Council take to decide?+
How much do planning drawings cost in Lewisham?+
Get your free Deptford planning assessment
Tell us your Deptford (SE8) address and ambition — we'll confirm feasibility, local constraints and a fixed fee within one working day.