
Double Storey Extension Drawings in Southgate Green N14
Fixed-fee, MCIAT-chartered double storey extension drawings for Southgate Green (N14) homeowners — London Borough of Enfield validation and local constraints handled from the start.
Southgate (N14) is anchored by Southgate Green, a historic green ringed by Georgian and Victorian houses and more than thirty listed structures, with Edwardian and interwar semis on the surrounding streets where most of our extension and loft work sits.
Because the Article 4(2) directions made in 2009 remove permitted-development rights on frontages inside the conservation area, we check the mapped boundary and listing status before advising whether a scheme is genuinely PD or needs a full application with heritage justification.


Planning in Southgate Green (N14): what to know before you apply
Most Southgate extensions run as householder applications to Enfield, with a heritage statement where the property is inside the Southgate Green Conservation Area. The 2009 Article 4(2) directions remove PD rights on street-facing elevations, and listed-building consent can be required near the green, so we confirm boundary and listing status first.
Typical Southgate Green housing stock
A historic green fringed by Georgian and early Victorian houses and over thirty listed buildings and structures, giving way to Edwardian and interwar semis and villas on the surrounding N14 streets around Conway Road.
Streets we regularly draw for in Southgate Green
The Green · Conway Road · Waterfall Road · Ulleswater Road
What N14 is actually built of
Measured from 310 classified residential buildings in N14, not from a description of the area.
Southgate Green N14 housing mix
Residential building form across the N14 postcode district, from 310 classified buildings.
| Attached on more than one side | 20% |
|---|---|
| Attached on one side | 70% |
| Detached | 10% |
| Median building footprint | 80 m² |
| Addresses per buildingAbove about 2 means flats and maisonettes dominate | 1.25 |
| Buildings classified | 310 |
Source: Ordnance Survey National Geographic Database (derived statistics). Contains OS data © Crown copyright and database right 2026. Contains Royal Mail data © Royal Mail copyright and database right 2026. Extracted 2026-08-17.
Double Storey Extension Drawings for Southgate Green (N14) homes: the package and the process
At first-floor level the drawings have to answer for daylight, privacy and massing. That means proposed elevations showing every new window with its position relative to the boundary, a section taken through the extension and the neighbouring building, and a roof form drawn to sit below the existing ridge rather than compete with it.
We draw the neighbouring property alongside your own, because the officer's assessment is comparative — the effect on their windows and outlook is the test. Setting the first floor in from the boundary, and showing that set-back as a dimension, resolves most objections before consultation begins.
At first floor the boundary relationship decides everything. A detached house has room to set the addition in on both sides; a semi has one shared wall and one clear flank; a mid-terrace can usually only go to the rear, where the effect on both neighbours has to be drawn.
Do I need planning permission for a double storey extension in London?
Almost always. Permitted development rights for two-storey extensions are far more restrictive than for single-storey work, particularly on how close the new structure can come to a boundary and how closely its roof pitch and eaves height must match the existing house, so most double storey projects are drawn and submitted as full householder planning applications rather than relying on permitted development.
Where the property sits in a conservation area or is subject to an Article 4 direction, any remaining permitted development allowance for a second storey is typically removed entirely, reinforcing the need for a full application. We check your property's status and your borough's design guidance before drawing.
How do councils control the impact of a double storey extension on neighbours?
Because a second storey introduces new windows and massing at first-floor level, London boroughs apply design guidance aimed specifically at protecting neighbouring light, privacy and outlook.
- The 45-degree rule, tested at neighbouring windows, to check the extension does not block an unreasonable amount of daylight
- A common design expectation that a two-storey side extension is set in roughly 1 metre from the shared boundary, rather than built hard against it
- A first floor commonly set back from the ground floor front elevation, so the upper storey reads as subordinate to the main house from the street
- Obscure or high-level glazing on flank walls facing directly into a neighbour's garden or windows, to limit overlooking
Matching the roofline and materials
Planning officers assess a double storey extension heavily on how convincingly it reads as part of the original house rather than an addition bolted onto the side. Our drawings match ridge height, roof pitch, eaves detail and brick or render finish to the existing building wherever the design brief allows, which is consistently one of the strongest factors in securing approval without delay or redesign. Where a subtly contrasting material is proposed instead — a different brick tone, or a zinc or slate roof against a tiled original — we set it out clearly on the elevations so the design intent reads as deliberate rather than a mismatch, which is how most London boroughs prefer a genuine design statement to be presented.
| Option | What it adds | Typical fee |
|---|---|---|
| Single-storey rear extension | A ground-floor kitchen-diner only, may qualify for permitted development | see Rear Extension Drawings, from £1,100 |
| Double storey side or rear extension | Two rooms across two floors, usually needs full planning | Full Planning pack ~£1,600–£2,400 |
| Double storey + Building Regulations (structural) | Combined pack including structural calculations for two-floor loads and foundations | Planning + Building Regs pack ~£2,200–£3,850 |
| Wraparound (rear + side return) | Combines two single-storey extensions into one L-shaped ground floor | see Wraparound Extension Drawings, from £2,200 |

Double Storey Extension Drawings in Southgate Green N14 — FAQs
How much does a double storey extension cost to design in London?+
Do I need planning permission to add a second storey?+
Will a double storey extension overlook my neighbour's garden?+
Do I need an architect for a double storey extension?+
How long does it take to get double storey extension drawings?+
Do I need planning permission for a loft or extension in Enfield?+
How does green-belt land affect my Enfield project?+
What does Enfield's borough-wide HMO Article 4 direction affect?+
How long does Enfield Council take to decide?+
How much do planning drawings cost in Enfield?+
Get your free Southgate Green planning assessment
Tell us your Southgate Green (N14) address and ambition — we'll confirm feasibility, local constraints and a fixed fee within one working day.