Basement Conversion Drawings in New Cross SE14
Fixed-fee, MCIAT-chartered basement conversion drawings for New Cross (SE14) homeowners — London Borough of Lewisham validation and local constraints handled from the start.
New Cross (SE14) climbs from the busy New Cross Road up into the Victorian streets of Telegraph Hill and the terraces behind Hatcham, and our work here is mostly rear extensions, side returns and loft conversions on that period housing.
Both the Telegraph Hill and Hatcham conservation areas carry Article 4 directions, so several normally-permitted changes need consent, and we check the boundary and the direction before advising on a permitted-development or full householder route.


Planning in New Cross (SE14): what to know before you apply
Inside the Telegraph Hill or Hatcham conservation areas the Article 4 directions mean front-facing and roof changes usually need planning permission. We confirm the designation for your street and prepare drawings to Lewisham standards.
Typical New Cross housing stock
Telegraph Hill is a largely residential grid of steep Victorian streets and villas above New Cross, while Hatcham combines commercial frontages on New Cross Road with Victorian terraces behind, plus later flats and student housing.
Streets we regularly draw for in New Cross
Pepys Road · Jerningham Road · Kitto Road · Erlanger Road
What SE14 is actually built of
Measured from 196 classified residential buildings in SE14, not from a description of the area.
New Cross SE14 housing mix
Residential building form across the SE14 postcode district, from 196 classified buildings.
| Attached on more than one side | 71% |
|---|---|
| Attached on one side | 27% |
| Detached | 2% |
| Median building footprint | 63 m² |
| Addresses per buildingAbove about 2 means flats and maisonettes dominate | 2.19 |
| Buildings classified | 196 |
Source: Ordnance Survey National Geographic Database (derived statistics). Contains OS data © Crown copyright and database right 2026. Contains Royal Mail data © Royal Mail copyright and database right 2026. Extracted 2026-08-17.
Basement Conversion Drawings for New Cross (SE14) homes: the package and the process
A basement package is led by its section. It has to show the existing structure, the proposed floor level, retained or underpinned walls, the tanking system, and how the finished room achieves head height without undermining what sits above. Structural design and architectural design are drawn together because here they are the same decision.
Habitable basement rooms also need light, ventilation and escape. The drawings set out lightwells and their guarding, mechanical ventilation where natural is not achievable, and an escape route that Building Control will accept — usually a protected stair, sometimes an external route out of the lightwell.
What sits below the house decides the route. An existing cellar under a Victorian terrace is a conversion with a known volume, while a house with no cellar is a dig-out with underpinning, structural design and a very different drawing set — and the two are rarely interchangeable.
Do I need planning permission for a basement conversion in London?
An internal conversion of an existing cellar — new floor, insulation, a habitable layout — often does not need planning permission, because the works sit entirely within the existing structure and do not change its external appearance. Digging out a new basement, lowering an existing floor to gain headroom, or enlarging the footprint under a garden usually does, particularly where excavation extends beyond the existing building line. Any external alteration needed to serve the basement — a front light well, a sunken external staircase, or altering the pavement or front garden — is also likely to need planning permission in its own right, even when the basement works themselves would not. In a conservation area, a front light well tends to draw closer scrutiny than the same feature elsewhere, since it changes the street-facing elevation and the pavement it sits within — one more reason we assess the whole scheme, not just the room below ground, before recommending a route.
Cellar conversion or new dig-out — which route fits your property?
The two starting points lead to very different drawing sets. A cellar conversion works with a void that already exists: the drawings focus on damp-proofing, insulation, headroom, natural or borrowed light, means of escape and a compliant layout, coordinated with building regulations rather than planning.
A new dig-out or floor-lowering project starts from a structural decision — how the existing foundations will be underpinned to allow excavation beneath them — and the drawings and structural calculations are produced together from the outset, since the sequence of underpinning, temporary works and waterproofing has to be engineered before a builder can safely start.
What structural design does underpinning a basement need?
Lowering a floor or digging a new basement beneath an existing house means underpinning its foundations in sequenced sections, so the building above stays supported throughout. We produce the structural drawings and calculations for the underpinning sequence, any new steel beams or retaining walls, and the interaction with neighbouring foundations, in-house as part of the same package — so your structural engineer sign-off and your architectural drawings are never out of step with each other.
The sequencing matters as much as the sizing: underpinning is dug and cast in short, alternating sections so the existing wall is never left unsupported over any significant length, and the drawings set out the order those sections are worked in alongside the retaining and waterproofing detail. Getting that sequence wrong is one of the most common causes of cracking and delay on a basement project, which is why we treat it as a design decision rather than something left for the contractor to work out on site.
| Route | Typical scope | Planning position | Fee from |
|---|---|---|---|
| Existing cellar conversion | Fit-out of an existing void, no excavation | Usually building regulations only | £2,400 |
| Floor lowering / partial dig-out | Increases headroom within the existing footprint | Often needs planning permission | £3,200 |
| New-build basement or light well extension | New basement area beyond the existing footprint | Full planning plus Party Wall Act | £3,850 |

Basement Conversion Drawings in New Cross SE14 — FAQs
How much do basement conversion drawings cost in London?+
Does a basement conversion need planning permission?+
Will I need a party wall agreement for a basement conversion?+
Are structural calculations included in a basement conversion package?+
Do I need an architect for a basement conversion?+
Do I need planning permission for a side-return extension in Lewisham?+
What does Lewisham's borough-wide HMO Article 4 direction affect?+
Can I convert the loft on my Lewisham terrace?+
How long does Lewisham Council take to decide?+
How much do planning drawings cost in Lewisham?+
Get your free New Cross planning assessment
Tell us your New Cross (SE14) address and ambition — we'll confirm feasibility, local constraints and a fixed fee within one working day.