
HMO Conversion Drawings in Greenford UB6
Fixed-fee, MCIAT-chartered hmo conversion drawings for Greenford (UB6) homeowners — London Borough of Ealing validation and local constraints handled from the start.
Greenford (UB6) is classic outer-west-London Metro-land: broad avenues of interwar semis with deep gardens, ideal for rear and wraparound kitchen extensions, loft conversions with rear dormers, and garage-to-room conversions. Most householder projects here fall squarely within permitted development or a straightforward Ealing Council householder application.
The one sensitivity is the Canalside conservation area on the neighbourhood's north-west flank near the Grand Union, where materials and rear massing get closer scrutiny. We prepare drawings that hold the interwar building line and gap-to-boundary rhythm Ealing's officers expect, and flag any canal-edge or former-industrial plot early so ground and drainage issues are designed out.


Planning in Greenford (UB6): what to know before you apply
No published householder Article 4 direction in Greenford, so most extensions and lofts run under permitted development or a standard Ealing householder application. Properties bordering the Canalside conservation area lose some permitted-development rights, and rear/side extension depths are assessed against the neighbouring semis' building line.
Typical Greenford housing stock
Greenford is dominated by 1920s-30s bay-fronted semis and short terraces laid out along wide suburban avenues, many with generous rear gardens and original hipped roofs. Nearer the Grand Union Canal and the old Rockware/Lyon works, plots give way to former industrial land and later flat-roofed infill.
Streets we regularly draw for in Greenford
Oldfield Lane North · The Fairway · Costons Avenue · Rockware Avenue
HMO Conversion Drawings for Greenford (UB6) homes: the package and the process
Every hmo conversion drawings we prepare for an Greenford property is drawn to London Borough of Ealing’s validation standards and tuned to the UB6 constraints above. Here is what the drawing package covers and how the process runs from first survey to approval.
A House in Multiple Occupation (HMO) is a property let to three or more unrelated occupants sharing kitchen, bathroom or living facilities. A small HMO — three to six sharers — normally falls into Use Class C4, while a large HMO of seven or more occupants is sui generis, sitting entirely outside the Use Classes Order. Both routes trigger licensing requirements, and in many London boroughs an Article 4 direction removes the usual permitted development right to convert a family home (C3) into a small HMO (C4), meaning full planning permission is needed even for a straightforward conversion.
DrawingsDirect draws HMO conversions to the standard your borough's planning and licensing teams both expect — minimum room sizes, amenity provision, fire safety and means of escape — so one set of drawings supports both the planning application, where needed, and the licensing submission. We check whether an Article 4 direction applies to your property before you commit to a route, and coordinate fire safety and structural detail in-house.
C4 small HMO or sui generis large HMO — which applies to your property?
The distinction matters because it decides which rules apply. A small HMO housing three to six unrelated sharers who share amenities is Class C4. A large HMO of seven or more occupants is sui generis and always needs planning permission, since sui generis uses sit outside the permitted development system entirely. The line also shifts with occupancy — a property let to six sharers today can tip into sui generis territory the moment a seventh tenancy is signed, which changes the planning position even though nothing about the building itself has changed. We assess your proposed occupancy and layout against both definitions before drawing, so the application matches how the property will actually be let.
Do I need planning permission for an HMO conversion in London?
Converting a family home (C3) into a small HMO (C4) is technically permitted development under national rules, but a large number of London boroughs have made an Article 4 direction that removes this right across all or part of the borough — meaning a full planning application is required even for a small, compliant HMO. Article 4 directions vary street by street in some boroughs, so two similar houses a few doors apart can sit on opposite sides of the line. Any large HMO (sui generis) needs planning permission everywhere, regardless of Article 4. We check your specific address against the relevant borough's Article 4 direction before recommending a route, since guessing wrong wastes both time and application fees.
| Factor | C4 small HMO (3–6 sharers) | Sui generis large HMO (7+) |
|---|---|---|
| Use class | C4 | Sui generis |
| Planning permission | Often needed due to Article 4 directions in most boroughs | Always needed |
| Licensing | Mandatory if 5+ occupants; additional licensing in many boroughs | Mandatory |
| Typical drawing package | From £1,400 | Full planning + building regs, from £2,200 |
HMO Conversion Drawings in Greenford UB6 — FAQs
How much do HMO conversion drawings cost in London?+
Is HMO conversion permitted development in London?+
Do I need a licence as well as planning permission?+
Do I need an architect for an HMO conversion?+
How long do HMO conversion drawings take?+
Do I need planning permission for a rear extension in Ealing?+
What extra control applies in Bedford Park?+
How long does Ealing Council take to decide a householder application?+
Can you help with a loft conversion on a 1930s Ealing semi?+
How much do planning drawings cost in Ealing?+
Get your free Greenford planning assessment
Tell us your Greenford (UB6) address and ambition — we'll confirm feasibility, local constraints and a fixed fee within one working day.